dc.identifier.urihttp://repositorio.ucsg.edu.ec/handle/3317/10140-
dc.descriptionEste trabajo de título consiste en la implementación de una metodología simplificada de gestión de presiones, para la reducción de volúmenes de fugas en sistemas de abastecimiento de agua potable. Los pocos datos empleados para su desarrollo, fueron medidos dentro el sector en estudio, representado por la ciudadela “La Atarazana” perteneciente a la zona urbana de la ciudad de Guayaquil. Las mediciones realizadas se ejecutaron en un período de siete días consecutivos, los cuales entraron en un proceso de depuración, dando como consiguiente una tabla representativa de 24 horas.Gracias a la aplicabilidad de la ecuación FAVAD, se consiguió determinar el comportamiento hidráulico real de la red, con un nivel de proximidad presión-caudal bastante acertado, al momento de ejecutar regulaciones de presión fija y activa en la entrada del sistema de abastecimiento. Una vez obtenidos los resultados de los análisis, se determinaron ciertas diferencias y conclusiones importantes entre estos tipos de regulación en mención.en_US
dc.description.abstractThis graduation project consists about an implementation of a simplified pressure management methodology for the reduction of leakage volumes in drinking water supplies systems. The few data used for this development were measured within the sector under study, represented by the zone named “La Atarazana” belonging to the city of Guayaquil. The measurements made were executed in a period of seven consecutive days, which entered a debugging process, giving as a result a representative 24-hour table. With the applicability of the FAVAD equation, it was possible to determine the real hydraulic behavior of the network, with a fairly accurate pressure -flow proximity level, when executing fixed and active pressure regulations at the input of the supply system. Once the results of the analyzes were obtained, certain important differences and conclusions were determined between these types of regulation in mention.en_US
dc.formatapplication/pdfen_US
dc.language.isospaen_US
dc.publisherUniversidad Católica de Santiago de Guayaquilen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/en_US
dc.subjectABASTECIMIENTO DE AGUAen_US
dc.subjectGESTIÓN DE PRESIONESen_US
dc.subjectDISTRIBUCIÓN DE AGUA POTABLEen_US
dc.subjectCOMPORTAMIENTO HIDRÁULICOen_US
dc.titlePropuesta metodológica simplificada de gestión de presiones para la recuperación de pérdidas reales en redes de distribución de agua potable.en_US
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US
Aparece en las colecciones: Trabajos de Titulación - Carrera de Ingeniería Civil

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
T-UCSG-PRE-ING-IC-233.pdf2,57 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons