dc.descriptionEl Acondicionador de envases de vidrio con el paso del tiempo pierde eficiencia aumentando el consumo de energía y combustible necesario para mantener la temperatura en cada periodo de trabajo; esto produce defectos críticos que afectan la productividad y calidad del producto final. El principal objetivo es optimizar el acondicionador de envases de vidrio mediante un diseño de control de temperatura por medio de variadores, el cual se ejecutara en varias etapas comenzando por la recopilación de información de las condiciones actuales de funcionamiento, seguido por el diseño de la estructura de control y finaliza con el cálculo de los elementos que repotencian el sistema eléctrico. La metodología de investigación que se utiliza es documental, descriptiva, experimental y aplicativa. Asimismo, se realizara un análisis económico que consiste en una aproximación del consumo eléctrico en el acondicionador para estimar el tiempo de recuperación de la inversión y determinar las ventajas de la optimización. Finalmente, con un adecuado análisis de las variables se espera lograr que la optimización del sistema ayude a mejorar la vida útil del equipo y cumplir los requerimientos de eficiencia, productividad y calidad del producto final exigido por el cliente.en_US
dc.description.abstractThe conditioner of glass containers with the passage of time loses efficiency increasing the consumption of energy and fuel necessary to maintain the temperature in each period of work; this produces critical defects that affect the productivity and quality of the final product. The main objective is to optimize the glass container conditioner by means of a temperature control design by means of inverters, which will be executed in several stages starting from the collection of information of the current operating conditions, followed by the design of the structure of control and ends with the calculation of the elements that repower the electrical system. The research methodology used is documentary, descriptive, experimental and applicative. Likewise, an economic analysis will be carried out that consists of an approximation of the electrical consumption in the conditioner to estimate the recovery time of the investment and determine the advantages of the optimization. Finally, with an adequate analysis of the variables, it is expected that the optimization of the system will help to improve the useful life of the equipment and meet the requirements of efficiency, productivity and quality of the final product demanded by the customer.en_US
dc.formatapplication/pdfen_US
dc.language.isospaen_US
dc.publisherUniversidad Católica de Santiago de Guayaquilen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/en_US
dc.subjectCONTROLES ELÉCTRICOSen_US
dc.subjectINSTALACIONES ELÉCTRICASen_US
dc.subjectACONDICIONADOR DE ENVASES DE VIDRIOen_US
dc.subjectVENTILADORES DE RECIRCULACIÓNen_US
dc.subjectCONTROLADORES DE TEMPERATURAen_US
dc.subjectQUEMADORESen_US
dc.subjectSENSOR INDUCTIVOen_US
dc.titleEstudio y diseño de un sistema de control de temperatura mediante variadores que optimizan la producción de envases de vidrio en la compañía Cridesa.en_US
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US