Veuillez utiliser cette adresse pour citer ce document :
http://repositorio.ucsg.edu.ec/handle/3317/13377
Affichage complet
Élément Dublin Core | Valeur | Langue |
---|---|---|
dc.contributor.advisor | Bohórquez Escobar, Celso Bayardo | - |
dc.contributor.author | Echeverría Cruz, Jonathan Gabriel | - |
dc.date.accessioned | 2019-10-01T18:45:13Z | - |
dc.date.available | 2019-10-01T18:45:13Z | - |
dc.date.issued | 2019-09-16 | - |
dc.identifier.uri | http://repositorio.ucsg.edu.ec/handle/3317/13377 | - |
dc.description | En el presente trabajo de titulación como objetivo general se enfoca en realizar una guía metodológica para realizar la sustitución del refrigerante R- 22 por el R-290 en acondicionadores de aire tipo ventana de 24.000 btu. Para ello se estudió y analizo el comportamiento de ambos refrigerantes. La metodología que se empleó fue documental, descriptiva y explicativa. Para analizar este comportamiento nos basamos en los datos y características que tienen cada refrigerante así como, los diagramas de Mollier, tablas de presiones/temperaturas, aceites compatibles, características físicas, químicas y termodinámicas. Se plasman las propiedades de ambos refrigerantes y se analiza el trabajo que realizaría el compresor con ambos refrigerantes en base a datos teóricos. Se plantea los pasos a seguir en la metodología para la reconversión, así como también los pasos a seguir cuando un equipo no esté listo para la sustitución del refrigerante y presenten daños como fuga de gas refrigerante y compresor averiado. Se espera que con este trabajo se contribuya a la reutilización de los equipos que fueron diseñados para operar con R-22, a mejorar la eficiencia energética y reducir el impacto ambiental que se genera con el uso de los refrigerantes. | en_US |
dc.description.abstract | In this titration work, as a general objective, it focuses on carrying out a methodological guide to replace the R-22 refrigerant with the R-290 in 24,000 btu window type air conditioners. For this, the behavior of both refrigerants was studied and analyzed. The methodology used was documentary, descriptive and explanatory. To analyze this behavior, we rely on the data and characteristics of each refrigerant as well as the Mollier diagrams, pressure / temperature tables, compatible oils, physical, chemical and thermodynamic characteristics. The properties of both refrigerants are reflected and the work of the compressor with both refrigerants is analyzed based on theoretical data. The steps to follow in the methodology for the conversion are considered, as well as the steps to follow when a device is not ready for the replacement of the refrigerant and presents damages such as leakage of refrigerant gas and broken compressor. It is expected that this work will contribute to the reuse of equipment that was designed to operate with R-22, improve energy efficiency and reduce the environmental impact generated by the use of refrigerants. | en_US |
dc.format | application/pdf | en_US |
dc.language.iso | spa | en_US |
dc.publisher | Universidad Católica de Santiago de Guayaquil | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/4.0/ | en_US |
dc.subject | REFRIGERANTES | en_US |
dc.subject | EFICIENCIA ENERGÉTICA | en_US |
dc.subject | RECONVERSIÓN | en_US |
dc.subject | REFRIGERACIÓN | en_US |
dc.subject | CLIMATIZACIÓN | en_US |
dc.title | Metodología para el uso del R290 en sustitución del R22 en acondicionadores de aire tipo ventana ubicados en la Facultad de Educación Técnica para el Desarrollo de la UCSG para mejorar su eficiencia energética. | en_US |
dc.type | info:eu-repo/semantics/bachelorThesis | en_US |
Collection(s) : | Trabajos de Titulación - Carrera de Ingeniería en Eléctrico-Mecánica |
Fichier(s) constituant ce document :
Fichier | Description | Taille | Format | |
---|---|---|---|---|
T-UCSG-PRE-TEC-IEM-221.pdf | 2,13 MB | Adobe PDF | Voir/Ouvrir |
Ce document est autorisé sous une licence de type Licence Creative Commons