DSpace logo
Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.ucsg.edu.ec/handle/3317/14257
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorAmpuero Ramírez, Nelly Patricia-
dc.contributor.authorSolórzano Muñoz, María Johana-
dc.date.accessioned2020-03-16T20:11:34Z-
dc.date.available2020-03-16T20:11:34Z-
dc.date.issued2020-03-03-
dc.identifier.urihttp://repositorio.ucsg.edu.ec/handle/3317/14257-
dc.descriptionIntroducción: La microfiltración marginal es la entrada de bacterias y fluidos a la interfase restauración-diente, desencadenando diferentes causas que afectan la longevidad de la restauración. Objetivo: Determinar la eficacia de la fotopolimerización de las lámparas de fotocurado Elipar 3M y Bluephase en restauraciones de clase I en terceros molares. Material y métodos: Este estudio in vitro se estableció con una muestra de 80 terceros molares extraídos sanos dentro de la clínica de odontología UCSG en ciclo B-2019. Resultados: De la investigación realizada en los 8 grupos fotopolimerizados con las lámparas Elipar 3M y Bluephase Ivoclar, se encontró una totalidad de microfiltración en grado 2 y 3 en ambas lámparas cuando se fotopolimerizó a 10, 20, 30 y 40 segundos a 6 mm de distancia. Discusión: Estudios realizados por Domínguez27 recomienda en su estudio que las lámparas deben colocarse a una distancia de 2 a 6 mm para una adecuada fotopolimerización, nuestros resultados no presentaron concordancia con Dominguez ya que los resultados con mayor índice de microfiltracion fueron los de mayor distancia. Conclusión: Se llegó a la conclusión que al utilizar las lámparas a mayor distancia, se produjo una menor fotopolimerización de las muestras lo que ocasionó microfiltración en su totalidad, en diferentes grados.en_US
dc.description.abstractINTRODUCTION: Marginal microfiltration is the entry of bacteria and fluids to the tooth restoration interfase, triggering different causes that affect the longevity of the restoration. AIM: Determine the efficacy of the light curing of the Elipar 3M vs Bluephase Ivoclar light curing lamps in class I restorations in third molars. MATERIALS AND METHODS: This in vitro study was established with a sample of 80 healthy extracted third molars within the UCSG dental clinic in cycle B-2019. RESULTS: From the research carried out in the 8 light-cured groups with the Elipar 3M and Bluephase lamps, a total of 2 to 3 grade microfiltration was found in both lamps when light-curing at 10, 20.30 and 40 seconds at 6 mm distance. DISCUSSION: Studies conducted by Dominguez27 recommended in his study that the lamps should be placed at a distance of 2 to 6 mm for adequate photopolymerization, our results did not agree with Dominguez since the results with the highest microfiltration index were those with the greatest distance. CONCLUSION: It was concluded that when using the lamps at a greater distance, there was a lower photopolymerization of the samples which caused microfiltration in its entirety, in different grades.en_US
dc.formatapplication/pdfen_US
dc.language.isospaen_US
dc.publisherUniversidad Católica de Santiago de Guayaquilen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/en_US
dc.subjectODONTOLOGÍA RESTAURADORAen_US
dc.subjectESTÉTICA DENTALen_US
dc.subjectMICROFILTRACIÓNen_US
dc.subjectRESINAS COMPUESTASen_US
dc.subjectFOTOPOLIMERIZACIÓNen_US
dc.titleEfectividad de fotopolimerización de resinas compuestas en relación al uso de las lámparas de fotocurado parte II.en_US
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US
Aparece en las colecciones: Trabajos de Titulación - Carrera de Odontología

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
T-UCSG-PRE-MED-ODON-518.pdf9,85 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons