dc.description | En el presente trabajo de titulación se realiza la comparación del comportamiento de cinco edificios los cuales tienen diferentes parámetros de diseño y tipologías estructurales. Se realiza un modelo en base a un sismo de diseño con un periodo de retorno (Tr) de 475 años y cuatro modelos en base a un nuevo método basado en un sismo con un periodo de retorno de 43 años. Todos los modelos cumplen los lineamientos de la Normativa ACI- 318-19 siguiendo los detalles de pórticos especiales resistentes a momentos (SMF) y pórticos intermedios resistentes a momentos (IMF). Un modelo cumple con el lineamiento propuesto por la NEC-15 con una deriva admisible del 2% y los otros modelos se limitan a una deriva del 0.5%. Con los resultados de los diseños, se calculan las áreas, cantidades de materiales (hormigón y acero) y se comparan. Se deja abierto el tema para, en una segunda entrega, se revise el desempeño esperado para cada uno de los modelos propuestos. | en_US |
dc.description.abstract | n this degree work, a comparison of the behavior of five buildings with different design parameters and structural typologies is carried out. One model is based on a design earthquake with a return period (Tr) of 475 years and four models are based on a new method based on an earthquake with a return period of 43 years. All models comply with the guidelines of ACI-318- 19 following the details of special moment resisting frames (SMF) and intermediate moment resisting frames (IMF). One model complies with the NEC-15 guidelines with a 2% allowable drift and the other models are limited to 0.5% drift. With the results of the designs, areas, quantities of materials (concrete and steel) are calculated and compared. The topic is left open for a second installment to review the expected performance for each of the proposed models. | en_US |
dc.format | application/pdf | en_US |
dc.language.iso | spa | en_US |
dc.publisher | Universidad Católica de Santiago de Guayaquil | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/4.0/ | en_US |
dc.subject | ESTRUCTURA SÍSMICA | en_US |
dc.subject | SISMO DE DISEÑO | en_US |
dc.subject | PÓRTICOS | en_US |
dc.subject | DERIVAS | en_US |
dc.subject | SOBRERRESISTENCIA | en_US |
dc.title | Influencia de parámetros en el método alternativo de diseño sismo-resistente parte I. | en_US |
dc.type | info:eu-repo/semantics/bachelorThesis | en_US |
Aparece en las colecciones: | Trabajos de Titulación - Carrera de Ingeniería Civil |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
T-UCSG-PRE-ING-IC-417.pdf | 2,04 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons