dc.descriptionINTRODUCCIÓN: Para lograr una óptima polimerización de las resinas compuestas, material utilizado ampliamente en la odontología actualmente, las características de las lámparas de fotopolimerización son de mucha importancia. La profundidad de polimerización que estas proporcionan es un aspecto determinante para el éxito clínico de las restauraciones. OBJETIVO: Medir la profundidad de polimerización de lámparas utilizadas en la clínica de odontología UCSG. MATERIALES Y MÉTODOS: Para el estudio se utilizaron 10 lámparas y posteriormente se confeccionaron 10 grupos de 20 especímenes de resina utilizando un molde de acero inoxidable. Por cada lámpara a evaluar se realizaron 10 especímenes de resina Brilliant EverGlow OA3 y 10 de resina Brilliant EverGlow A1/B1. Estos 10 especímenes se dividieron en dos grupos de 5, fotopolimerizando cada uno a diferentes distancias: 0mm y 10 mm respectivamente, medidas desde la punta de la lámpara hasta la resina. RESULTADOS: La resina que logro mayor profundidad de curado fue la resina Brilliant EverGlow A1/B1. Se comprobó que la distancia de la punta de la lámpara al objetivo influye radicalmente en su nivel de polimerización. La irradiancia de las lámparas no tuvo relación con la profundidad de curado. La lámpara Bluephase N ivoclar vivadent fue la que logró mayor profundidad de curado. En promedio, el espesor de composite que polimeriza para el color A1/B1 fue de 2mm, mientras que para el color OA3 fue de 1mm. CONCLUSIÓN: Existen diferencias en las características de las lámparas en su polimerización, las de bajo costo dieron los valores más bajos de profundidad de curado.en_US
dc.description.abstractINTRODUCTION: To achieve optimal polymerization of composite resins, a material widely used in dentistry today, the characteristics of light-curing lamps are very important. The depth of polymerization that they provide is a determining factor for the clinical success of the restorations. OBJECTIVE: To measure the depth of polymerization of lamps used in the UCSG dental clinic. MATERIALS AND METHODS: For the study, 10 lamps were used and later 10 groups of 20 resin specimens were made using a stainless-steel mold. For each lamp to be evaluated, 10 Brilliant EverGlow OA3 resin specimens and 10 Brilliant EverGlow A1/B1 resin specimens were made. These 10 specimens were divided into two groups of 5, light-curing each one at different distances: 0mm and 10mm respectively, measured from the tip of the lamp to the resin. RESULTS: The resin that achieved the greatest depth of cure was the Brilliant EverGlow A1/B1 resin. It was found that the distance from the tip of the lamp to the objective radically influences its level of polymerization. The irradiance of the lamps was not related to the depth of cure. The Bluephase N ivoclar vivadent lamp achieved the greatest depth of cure. On average, the thickness of the composite that polymerizes for the A1/B1 shade was 2mm, while for the OA3 shade it was 1mm. CONCLUSION: There are differences in the characteristics of the lamps in their polymerization, the low-cost ones gave the lowest values of curing depth.en_US
dc.formatapplication/pdfen_US
dc.language.isospaen_US
dc.publisherUniversidad Católica de Santiago de Guayaquilen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/en_US
dc.subjectODONTOLOGÍA RESTAURADORAen_US
dc.subjectREHABILITACIÓN ORALen_US
dc.subjectRESINA COMPUESTAen_US
dc.subjectPOLIMERIZACIÓN DENTALen_US
dc.subjectPROFUNDIDAD DE CURADOen_US
dc.subjectFOTOACTIVACIÓNen_US
dc.titleProfundidad de polimerización de lámparas utilizadas en la clínica de odontología UCSG, estudio in vitro.en_US
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US