DSpace logo
Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.ucsg.edu.ec/handle/3317/21291
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorRamírez Barriga, María Isabel-
dc.contributor.authorCoronel Mite, Ana Paula-
dc.contributor.authorMosquera Ceprian, Rafael Andrés-
dc.date.accessioned2023-07-13T19:13:43Z-
dc.date.available2023-07-13T19:13:43Z-
dc.date.issued2023-05-01-
dc.identifier.urihttp://repositorio.ucsg.edu.ec/handle/3317/21291-
dc.descriptionObjetivo: Identificar la prevalencia de los trastornos de conducción cardiaca en los pacientes sometidos a implante valvular aórtico transcatéter. Métodos y resultados: Este es un estudio de tipo descriptivo, retrospectivo, que incluyo a todos los pacientes diagnosticados con estenosis aortica desde el año 2020 hasta el 2022, siendo un total de 65 pacientes registrados en el sistema del Hospital Luis Vernaza. Se considero edad, sexo, factores de riesgo asociados, procedimiento llevado a cabo, tipo de prótesis valvular implantada, ritmo cardiaco post procedimiento, implante de marcapasos definitivo y mortalidad. Conclusión: La prevalencia de trastornos de conducción eléctrica fue de 6 pacientes TAVI, siendo el 9%. Los trastornos de conducción encontrados posterior al implante de válvulas autoexpandibles ,fueron bloqueo de rama izquierda (14%), bloqueo AV completo (14%), y trastornos inespecíficos de la repolarización ventricular (14%). Con la válvula autoexpandible, 14% de los pacientes requirieron marcapasos definitivo, con la expandida por balón 7%. La válvula autoexpandible presento 14% de anomalías de conducción, mientras que la inflada por balón tuvo un 7%. HTA fue el factor de riesgo más común, junto con la edad avanzada estando en el 79% de los individuos, un 36% de los pacientes tenía hipertrofia del ventrículo izquierdo como antecedente. La mortalidad fue del 0% en sometidos a TAVI, los pacientes que recibieron reemplazo de válvula por medio de cirugía convencional tuvieron el 6%.en_US
dc.description.abstractObjective: Identify the prevalence of cardiac conduction disorders in patients undergoing transcatheter aortic valve implantation. Methodology and results: This is a descriptive, retrospective study that included all patients diagnosed with aortic stenosis from 2020 to 2022, with a total of 65 patients registered in the Luis Vernaza Hospital system. Age, sex, associated risk factors, procedure performed, type of valve prosthesis implanted, post-procedure cardiac rhythm, definitive pacemaker implantation and mortality were considered. Conclusion: The prevalence of electrical conduction disorders on patients undergoing TAVI was 9% , the disorders found were left bundle branch block (14%), complete AV block (14%), and nonspecific ventricular repolarization disorders (14%). With the self-expandable valve, 14% of patients required definitive pacemaker, and 7% with the balloon-expanded valve. The selfexpandable valve had 14% of conduction anomalies, while the balloon-inflated valve had 7%. Hypertension was the most common risk factor, together with advanced age, being among 79% of the individuals, 36% of the patients had left ventricular hypertrophy as a background. Mortality was 0% in patients who underwent TAVI; patients who received valve replacement by conventional surgery had 6%.en_US
dc.formatapplication/pdfen_US
dc.language.isospaen_US
dc.publisherUniversidad Católica de Santiago de Guayaquilen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/en_US
dc.subjectESTENOSIS AÓRTICAen_US
dc.subjectENFERMEDAD DE LA VÁLVULA AÓRTICAen_US
dc.subjectARRITMIASen_US
dc.subjectBLOQUEO CARDÍACOen_US
dc.subjectMARCAPASOS CARDÍACOen_US
dc.titlePrevalencia de trastornos de conducción eléctrica tras el implante percutáneo transcatéter de válvula aórtica. Servicio de cardiología. Hospital Luis Vernaza. 2020 al 2022.en_US
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US
Aparece en las colecciones: Trabajos de Titulación - Carrera de Medicina

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
T-UCSG-PRE-MED-1520.pdf741,05 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons