dc.descriptionObjetivo: Evaluar la precisión de las mediciones obtenidas con dos biómetros ópticos de tecnología de fuente de barrido, el IOLMaster 700 y el Revo FC 130, en pacientes diagnosticados de cataratas. Métodos: Se realizó un estudio observacional, prospectivo y comparativo, donde se evaluaron pacientes mayores de 40 años con cataratas. Un mismo operador realizó la biometría óptica utilizando ambos dispositivos en la misma sesión. La clasificación de las cataratas se llevó a cabo mediante el Lens Opacity Classification System III. Resultados: Se obtuvieron mediciones biométricas de 504 ojos pertenecientes a 279 pacientes, con una edad promedio de 70,93 ± 8,41 años. Al comparar los valores obtenidos con el IOL- Master 700 y el Revo FC 130 se encontraron diferencias estadísticamente significativas entre: las queratometrías promedio (43,53 ± 1,56 y 44,27 ± 1,68 dioptrías); la queratometría total promedio y la queratometría promedio (43,56 ± 1,55 dioptrías y 44,27 ± 1,67 dioptrías); la relación blanco-a-blanco (11,98 ± 0,52 y 12,66 ± 0,73 mm) y el espesor del cristalino (4,53 ± 0,40 y 4,60 ± 0,40 mm). Mientras que no hubo una diferencia estadísticamente significativa al comparar la AL (23,31 ± 0,96 y 23,25 ± 1,01 mm) ni la profundidad de la cámara anterior (3,02 ± 0,38 y 3,02 ± 0,37 mm, no clínicamente relevante). Al comparar los valores obtenidos con el IOLMaster 700 de la queratometría total promedio (43,53 ± 1,56 dioptrías) y de la queratometría promedio (43,56 ± 1,56 dioptrías), no se hallaron diferencias significativas. Conclusiones: A pesar de que la mayoría de las medidas no presentan una diferencia clínica- mente relevante, ambos equipos no deberían ser intercambiables, debido principalmente a la no correlación entre las queratometrías.en_US
dc.description.abstractObjective: To evaluate the measurement accuracy of 2 swept-source optical biometers, the IOLMaster 700 and the Revo FC 130, in patients diagnosed with cataracts. Methods: We conducted a prospective, observational and comparative study in patients older than 40 years with cataracts. A single operator performed optical biometry using both devi- ces during the same session. Cataract grading was conducted using the Lens Opacities Classification System III. Results: Biometric measurements were obtained from the 504 eyes of 279 patients, with a mean age of 70.93 ± 8.41 years. Statistically significant differences were found between the IOLMaster 700 and Revo FC 130 in the following parameters: mean keratometry (43.53 ± 1.56 vs 44.27 ± 1.68 diopters), total average keratometry and mean keratometry (43.56 ± 1.55 diopters vs 44.27 ± 1.67 diopters), white-to-white distance (11.98 ± 0.52 vs 12.66 ± 0.73 mm), and lens thickness (4.53 ± 0.40 vs 4.60 ± 0.40 mm). No significant differences were found in axial length (23.31 ± 0.96 vs 23.25 ± 1.01 mm) or anterior chamber depth (3.02 ± 0.38 vs 3.02 ± 0.37 mm), which were not clinically relevant. No statistically significant differen- ces were found between the IOLMaster 700 measurements of total mean keratometry (43.53 ± 1.56 diopters) and mean keratometry (43.56 ± 1.56 diopters). Conclusions: Although most measurements do not reveal any clinically relevant differences, the 2 devices should not be used interchangeably, mainly due to variations in keratometry readings.en_US
dc.formatapplication/pdfen_US
dc.language.isospaen_US
dc.publisherUniversidad Católica de Santiago de Guayaquilen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/en_US
dc.subjectBIOMETRÍA OCULARen_US
dc.subjectFACOEMULSIFICACIÓNen_US
dc.subjectTOMOGRAFÍA DE COHERENCIA ÓPTICAen_US
dc.subjectCATARATAen_US
dc.subjectQUERATOMETRÍAen_US
dc.titleComparación de dos biómetros ópticos con tecnología de fuente de barrido : IOLMaster 700 vs. Revo FC 130.en_US