DSpace logo
Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.ucsg.edu.ec/handle/3317/26969
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorBarros Cabezas, José Andrés-
dc.contributor.authorArgüello Calero, Alicia Kamila-
dc.contributor.authorCampaña Vallejo, Shirley Fernanda-
dc.date.accessioned2026-09-29T20:25:22Z-
dc.date.available2026-09-29T20:25:22Z-
dc.date.issued2026-09-01-
dc.identifier.urihttp://repositorio.ucsg.edu.ec/handle/3317/26969-
dc.descriptionLa presente investigación evaluó el desempeño sísmico de una edificación patrimonial mediante los criterios de aceptación del ASCE/SEI 41- 17 y la Norma Ecuatoriana de la Construcción (NEC-15). Debido a la ausencia de ensayos in situ, se adoptó un nivel de conocimiento KL-1 y un factor de conocimiento k = 0.75. A partir del modelo estructural se representaron las condiciones existentes de la edificación y se evaluó su respuesta frente a acciones sísmicas. Las derivas máximas obtenidas fueron de 0.9 % para Seguridad de Vida (LS) y 1.7 % para Prevención del Colapso (CP), ambas inferiores al límite de 2.00 %. Asimismo, los efectos P-Δ y la irregularidad torsional cumplieron los criterios según la NEC-15. Para Seguridad de Vida, las vigas no cumplen los criterios de aceptación. Las columnas rectangulares y cuadradas cumplen todas las verificaciones en X (18 de 18), aunque en Y el cumplimiento baja a 15 de 18. Las circulares, en cambio, apenas alcanzan 1 de 3 en X y ninguna en Y. Esta misma tendencia se repite en Prevención del Colapso: 14 de 18 en X y 11 de 18 en Y para las secciones rectangulares y cuadradas, frente a un incumplimiento total de las circulares en ambas direcciones. Estos resultados confirman que no todos los elementos cumplen con lo exigido por la norma ASCE/SEI 41-17, siendo las columnas circulares las más críticas. Por ello, se recomienda plantear medidas de intervención estructural que mejoren su comportamiento.en_US
dc.description.abstractThis research evaluated the seismic performance of a heritage building using the acceptance criteria of ASCE/SEI 41-17 and the Ecuadorian Construction Standard (NEC-15). Due to the absence of in situ testing, a knowledge level of KL-1 and a knowledge factor of k = 0.75 were adopted. Based on the structural model, the existing conditions of the building were represented, and its response to seismic actions was evaluated. The maximum drifts obtained were 0.9% for Life Safety (LS) and 1.7% for Collapse Prevention (CP), both below the 2.00% limit. Likewise, the P-Δ effects and torsional irregularity met the criteria established by NEC-15. For the Life Safety, the beams do not meet the acceptance criteria. Rectangular and square columns meet all the checks in X (18 out of 18), although in Y the compliance drops to 15 out of 18. Circular ones, on the other hand, barely reach 1 out of 3 in X and none in Y. This same trend is repeated in Collapse Prevention: 14 of 18 in X and 11 of 18 in Y for the rectangular and square sections, in the face of a total breach of the circulars in both directions. These results confirm that not all elements comply with the requirements of the ASCE/SEI 41-17 standard, with circular columns being the most critical. Therefore, it is recommended to propose structural intervention measures that improve their performanceen_US
dc.formatapplication/pdfen_US
dc.language.isospaen_US
dc.publisherUniversidad Católica de Santiago de Guayaquilen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/en_US
dc.subjectPatrimonio culturalen_US
dc.subjectIngeniería sísmicaen_US
dc.subjectEvaluación estructuralen_US
dc.subjectSeguridad estructuralen_US
dc.subjectRehabilitación de edificiosen_US
dc.subjectTerremotosen_US
dc.titleEvaluación estructural del edificio "Casa de la Cultura Ecuatoriana", Núcleo del Guayas.en_US
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US
Aparece en las colecciones: Trabajos de Titulación - Carrera de Ingeniería Civil

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
UCSG-C388-26432.pdf6,89 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons