DSpace logo
Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.ucsg.edu.ec/handle/3317/11234
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorVasconez Gavilánez, José Ernesto-
dc.contributor.authorYánez Veloz, Miguel Ángel-
dc.date.accessioned2018-10-02T03:42:39Z-
dc.date.available2018-10-02T03:42:39Z-
dc.date.issued2018-09-13-
dc.identifier.urihttp://repositorio.ucsg.edu.ec/handle/3317/11234-
dc.descriptionEl presente trabajo de titulación se realizó con el fin de evaluar la eficiencia del tratamiento primario químicamente mejorado (CEPT), para las aguas residuales domesticas de la ciudad de Guayaquil, determinar el grado de eficiencia en la remoción de diversos parámetros físicos y químicos del agua residual tratada y evaluar si los niveles del efluente de la planta piloto están dentro de los limites aceptados de la norma técnica Texto Unificado de Legislación Secundaria Medioambiental (TULSMA) establecido por el Ministerio de ambiente del Ecuador. Mediante la prueba de jarras se encuentra la dosificación óptima del coagulante cloruro férrico (FeCl3), con diferentes dosificaciones para evaluar su eficiencia en remoción de contaminantes, para determinar la dosificación que se ajuste a los requerimientos técnicos y económicos. La construcción de una planta piloto constó de un equipo de bombeo para llevar las aguas servidas domésticas desde red de alcantarillado de la facultad de ingeniería de la Universidad Católica de Santiago de Guayaquil, instalaciones de dosificación del cloruro férrico y polímero, dos tanques: tanque mezcla rápida, coagulación-floculación, un segundo tanque para clarificación. Con la calibración de caudales para operar la planta piloto CEPT a flujo continuo. En esta circunstancia se procedió a la toma de muestras para realizar mediciones y proceder a la comparación con las eficiencias obtenidas en las pruebas de jarras. Se tabularon los resultados para analizar y establecer la mejor dosificación respecto a la remoción de los tres parámetros analizados y costos de cada uno de ellos por metro cúbico tratado.en_US
dc.description.abstractThis qualification work was carried out in order to evaluate the efficiency of the treatment (CEPT) chemically enhanced primary, for sewage domestic from the city of Guayaquil, determining the degree of efficiency in removal of various physical and chemical parameters of the treated wastewater and assess whether the pilot plant effluent levels are inside of the limits accepted technical standard text unified environmental secondary legislation (TULSMA) established by the Ministry of environment of the Ecuador. By jar test the optimal dosage of coagulant ferric chloride (FeCl3), meets different dosages to evaluate their efficiency in removal of contaminants, to determine the dosage which conforms to the requirements technical and economic. The construction of a pilot plant consisted of a pumping equipment to carry domestic wastewater from sewer system of the Engineering Faculty of the Catholic University of Santiago de Guayaquil, installations of dosing ferric chloride and polymer, two tanks: tank fast mixing, flocculation, a second tank for clarification. With the flow calibration to operate the pilot plant CEPT to continuous flow. In this circumstance was sampling measurements to make the comparison with the efficiencies obtained in tests of pitchers. Results were tabulated to analyse and establish the best dosage with respect to the removal of the three analysed parameters and costs of each one of them per cubic meter of treated.en_US
dc.formatapplication/pdfen_US
dc.language.isospaen_US
dc.publisherUniversidad Católica de Santiago de Guayaquilen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/en_US
dc.subjectTRATAMIENTO DE AGUAS RESIDUALESen_US
dc.subjectTRATAMIENTO PRIMARIO QUÍMICAMENTE MEJORADOen_US
dc.subjectRED ALCANTARILLADOen_US
dc.subjectCONTAMINACIÓN DE AGUAen_US
dc.titleEvaluación de la eficiencia del sistema tratamiento primario químicamente mejorado (CEPT, Chemically Enhanced Primary Treatment), para aguas residuales de Guayaquil.en_US
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US
Aparece en las colecciones: Trabajos de Titulación - Carrera de Ingeniería Civil

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
T-UCSG-PRE-ING-IC-270.pdf7,34 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons