DSpace logo
Please use this identifier to cite or link to this item: http://repositorio.ucsg.edu.ec/handle/3317/14371
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorVillacrés Sánchez, Alex Raúl-
dc.contributor.authorMoreno Román, Andrei Alexander-
dc.date.accessioned2020-05-01T17:05:23Z-
dc.date.available2020-05-01T17:05:23Z-
dc.date.issued2020-02-28-
dc.identifier.urihttp://repositorio.ucsg.edu.ec/handle/3317/14371-
dc.descriptionPara el siguiente trabajo de titulación se recopiló información de diferentes diarios que circulan a nivel nacional y que tengan registros de los sismos que han afectado a las provincias de Guayas y Manabí enfocándose en aquellos que mantienen su central de noticias en las zonas de estudio. De igual forma revistas, artículos nacionales e internacionales relacionados con la construcción, sitios web, informes técnicos, estudios de suelos y toda la información a la que se pudo tener acceso para corroborar los resultados presentados. Se identificó las catedrales, iglesias y templos que han presentado daños estructurales y arquitectónicos durante los diferentes sismos ocurridos en Ecuador a partir de 1977 y se creo un listado para casos de estudio. Para estos casos los sismos que más relevancia han tenido sobre sus estructuras son el del 18 de agosto de 1998 y 16 de abril del 2016. Se estudio cada caso he identifico el nivel de amenaza sísmica mediante curvas de peligro, además en base a sus periodos se pudo establecer que tipo de sismo afecto a la edificación: frecuente, ocasional, raro y muy raro. Para realizar espectros de repuesta de sitio y diseño se uso datos obtenidos de diferentes estaciones acelerográficas distribuidas las provincias de estudio, estos espectros nos permiten conocer cuanto se desplazo cada estructura y determinar si se cumplió con lo establecido en la Norma Ecuatorial de la Construcción (NEC - 15).en_US
dc.description.abstractFor the following degree work, information was collected from different newspapers that circulate nationally and that have records of the earthquakes that have affected the provinces of Guayas and Manabí focusing on those that maintain their news center in the study areas. Similarly, magazines, national and international articles related to construction, websites, technical reports, soil studies and all the information that could be accessed to corroborate the results presented were consulted. The cathedrals, churches and temples that have presented structural and architectural damage during the different earthquakes that occurred in Ecuador since 1977 were identified and a list was created for case studies. For these cases, the earthquakes that have had more relevance on the structures are that of August 4, 1998 and April 16, 2016. Each case was studied, and the level of seismic risk was identified by hazard curves, also based on their vibration periods, it was possible to establish what type of earthquake affected the building: frequent, occasional, rare and very rare. To carry out site and design response spectra, data obtained from different accelerographic stations distributed in the provinces of study were used, these spectra allow us to know how much each structure moves and determine if it complies with what is established in (NEC - 15).en_US
dc.formatapplication/pdfen_US
dc.language.isospaen_US
dc.publisherUniversidad Católica de Santiago de Guayaquilen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/en_US
dc.subjectEDIFICACIONESen_US
dc.subjectTEMPLOS HISTÓRICOSen_US
dc.subjectESTRUCTURAen_US
dc.subjectVULNERABILIDADen_US
dc.subjectFACTORESen_US
dc.subjectESPECTRO DE RESPUESTAen_US
dc.subjectANÁLISIS DE COMPORTAMIENTOen_US
dc.subjectDESEMPEÑO SÍSMICOen_US
dc.titleDesempeño de edificios especiales durante sismos en Ecuador - caso de estudio : catedrales, iglesias, templos para las provincias de Guayas y Manabí.en_US
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US
Appears in Collections:Trabajos de Titulación - Carrera de Ingeniería Civil

Files in This Item:
File Description SizeFormat 
T-UCSG-PRE-ING-IC-333.pdf8,52 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons