Por favor, use este identificador para citar o enlazar este ítem:
http://repositorio.ucsg.edu.ec/handle/3317/15120
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Zambrano Bonilla, María Christel | - |
dc.contributor.author | Montalvo Rosado, Samanta Gabriela | - |
dc.date.accessioned | 2020-10-07T16:10:32Z | - |
dc.date.available | 2020-10-07T16:10:32Z | - |
dc.date.issued | 2020-09-15 | - |
dc.identifier.uri | http://repositorio.ucsg.edu.ec/handle/3317/15120 | - |
dc.description | Objetivo: Analizar los parámetros necesarios para que una restauración indirecta, no fracase al ser cementada con resina compuesta precalentada. Materiales y métodos: En el siguiente trabajo de investigación se realizó una revisión sistemática, descriptiva, no experimental. Se obtuvo un universo de 76 artículos de los cuales, se seleccionó una muestra de 40 artículos científicos. Resultados: En 16 artículos se evaluó resinas con diferentes tamaños de partículas de relleno, en 11 artículos se compararon las diferentes temperaturas a las que se puede exponer una resina sin afectar sus propiedades. En 13 estudios compararon el tiempo de fotocurado con el grosor de las restauraciones. Y se observó que en todos los artículos mencionan la viscosidad obtenida. Discusión: Las resinas compuestas microhíbridas, al ser expuesta a altas temperaturas, muestran una disminución de su viscosidad de más del 70%, y las nanohíbridas un 25%. Los dispositivos disponibles para precalentar las resinas funcionan en un rango de temperatura que va desde los 54 – 68°C. El grado de conversión depende del grosor de la restauración, es decir, el tiempo de polimerización puede ser de hasta 90 segundos por superficie si tenemos un espesor mayor a 1.5 mm. Conclusión: Se recomienda el uso de resinas microhíbridas a una temperatura de 68°C para reducir su viscosidad y poder ser utilizada como agente de cementación. | en_US |
dc.description.abstract | Purpose: Analyze the necessary parameters so that an indirect restoration does not fail when cemented with preheated composite resin. Materials and methods: In the following research work, a systematic, descriptive, non-experimental review was carried out. A universe of 76 articles was obtained, from which a sample of 40 scientific articles was selected. Results: Resins with different sizes of filler particles were evaluated in 16 articles, in 11 articles the different temperatures to which a resin can be exposed without affecting its properties were compared. In 13 studies they compared the light cure time with the thickness of the restorations. And it was observed that in all the articles they mention the viscosity obtained. Discussion: Microhybrid composite resins, when exposed to high temperatures, show a decrease in viscosity of more than 70%, and nanohybrid 25%. The devices available to preheat the resins operate in a temperature range that goes from 54 - 68°C. The degree of conversion depends on the thickness of the restoration, wich means that the polymerization time can be up to 90 seconds per surface if we have a thickness higher than 1.5 mm. Conclusion: The use of microhybrid resins at a temperature of 68 ° C is recommended to reduce its viscosity and be able to be used as a cementing agent. | en_US |
dc.format | application/pdf | en_US |
dc.language.iso | spa | en_US |
dc.publisher | Universidad Católica de Santiago de Guayaquil | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/4.0/ | en_US |
dc.subject | ODONTOLOGÍA RESTAURADORA | en_US |
dc.subject | PROSTODONCIA | en_US |
dc.subject | RESINAS COMPUESTAS MICROHÍBRIDAS | en_US |
dc.subject | AGENTES CEMENTANTES | en_US |
dc.title | Uso de resina compuesta precalentada como agente cementante en restauraciones indirectas : revisión de la literatura. | en_US |
dc.type | info:eu-repo/semantics/bachelorThesis | en_US |
Aparece en las colecciones: | Trabajos de Titulación - Carrera de Odontología |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
T-UCSG-PRE-MED-ODON-552.pdf | 720,33 kB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons