dc.descriptionSe presenta el trabajo de titulación, el cual tiene como objetivo principal diseñar un sistema de puesta a tierra que tolere las corrientes de cortocircuito durante el tiempo transcurrido entre la producción de la falla y la actuación de las protecciones e interruptores. Al diseñar un sistema puesta a tierra seguro evitaría que operase grupos electrógenos que en su desempeño de forma colateral puede existir consumo exagerado de combustible y derrames del mismo. Dicho trabajo emplea como metodología; el método descriptivo que genera un marco teórico sobre puesta a tierra y calidad de la energía eléctrica. Además, se emplea el método empírico por procedimientos de obtención de datos y manejo de equipo de medición de impedancias, resistividad del terreno. Se utilliza el método comparativo para evaluar criterios de mimetización a las estructuras metálicas de radiobases celulares. El resultado o propuesta de este trabajo de titulación es un diseño de puesta a tierra robusto para enviar corrientes a tierra, provenientes de eventos transitorios, tales como, descargas atmosféricas o por actuación de los pararrayos frente a sobretensiones, de tal manera que grupos electrógenos intervengan con poca frecuencia, así se cumple también criterios de gestión ambiental ISO 14001-2004 en cuanto a implantaciones de estaciones base con uso de energía eléctrica confiable.en_US
dc.description.abstracttitle work is presented, the main objective of which is to design a starting system that tolerates short-circuit currents during the time elapsed between the production of the fault and the actuation of the protections and switches. By designing a safe earthing system, it would prevent the operation of generating sets that in their performance could collaterally exist exaggerated fuel consumption and also spills of the same. As a methodology, it is used; the descriptive method that generates a theoretical framework on grounding and quality of electrical energy. The empirical method is used by procedures for obtaining data and handling equipment for measuring impedances, soil resistivity. The comparative method is used to evaluate criteria of mimicry to the metallic structures of cellular radio bases. The result or proposal of this qualification work is a robust earthing design to send currents to earth, originating from transient events, such as, atmospheric discharges or by the actuation of lightning rods against overvoltages, in such a way that generating sets intervene infrequently, thus, ISO 14001-2004 environmental management criteria are also met in terms of base station implantation with the use of reliable electrical energy.en_US
dc.formatapplication/pdfen_US
dc.language.isospaen_US
dc.publisherUniversidad Católica de Santiago de Guayaquilen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/en_US
dc.subjectENERGÍA ELÉCTRICAen_US
dc.subjectPUESTA A TIERRAen_US
dc.subjectDESCARGAS ELÉCTRICASen_US
dc.subjectGESTIÓN AMBIENTALen_US
dc.titleSistema eléctrico en radiobases celulares con medidas de mimetización en base a norma ISO 14001:2004.en_US
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US
Aparece en las colecciones: Trabajos de Titulación - Carrera de Ingeniería en Eléctrico-Mecánica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
T-UCSG-PRE-TEC-IEM-281.pdf4,42 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons