DSpace logo
Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.ucsg.edu.ec/handle/3317/19913
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorAlcívar Bastidas, Stefany Esther-
dc.contributor.authorCordero Hidalgo, José Francisco-
dc.contributor.authorPlaza Peñafiel, Bruno Eduardo-
dc.date.accessioned2022-11-08T02:35:55Z-
dc.date.available2022-11-08T02:35:55Z-
dc.date.issued2022-09-19-
dc.identifier.urihttp://repositorio.ucsg.edu.ec/handle/3317/19913-
dc.descriptionEl presente trabajo tiene el propósito de analizar la influencia en la capacidad de adherencia de un mortero reforzado con fibra de abacá previamente tratada con Hidróxido de Sodio (NaOH 3%), al igual que su comportamiento al reducir su porcentaje de cemento. Se realizará pruebas de compresión en cubos de 50mm de arista, flexión en probetas con medidas de acuerdo a las normas utilizadas y adherencia en bloques de hormigón para comparar tres distintas mezclas de mortero: Mortero convencional sin fibra (SF), mortero con fibra (CF) y mortero con fibra y reducción de cemento en un 10% (RC); para lo cual se ensayarán a 7 y 28 días de fraguado. Se presentará los pasos a tomar para el tratamiento de la fibra, la elaboración de las muestras, resultados de los ensayos, gráficos comparativos del comportamiento de los morteros, análisis de resultados y conclusión junto a una recomendación para trabajos investigativos posteriores.en_US
dc.description.abstractThe present research has the purpose of analyzing the influence on the adherence capacity of a mortar reinforced with abaca fiber previously treated with Sodium Hydroxide (NaOH 3%), as well as its behavior when reducing its percentage of cement. Compression tests will be carried out on cubes with an edge of 50mm, bending tests on specimens with measurements according to the standards used, and adhesion on concrete blocks to compare three different mortar mixes: conventional mortar without fiber (SF), mortar with fiber (CF) and mortar with fiber and cement reduction by 10% (RC); for which they will be tested at 7 and 28 days of setting. The steps to be taken for the treatment of the fiber, the elaboration of the samples, test results, comparative graphs of the behavior of the mortars, analysis of results and conclusion will be presented together with a recommendation for later investigative works.en_US
dc.formatapplication/pdfen_US
dc.language.isospaen_US
dc.publisherUniversidad Católica de Santiago de Guayaquilen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/en_US
dc.subjectINGENIERÍA EN MATERIALESen_US
dc.subjectMUSA TEXTILISen_US
dc.subjectSOSTENIBILIDADen_US
dc.subjectMORTEROen_US
dc.subjectTRATAMIENTO DE FIBRAen_US
dc.subjectNAOHen_US
dc.titleInfluencia de la fibra de abacá tratada en la adherencia de morteros en paredes de bloques.en_US
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US
Aparece en las colecciones: Trabajos de Titulación - Carrera de Ingeniería Civil

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
T-UCSG-PRE-ING-IC-446.pdf1,89 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons