Por favor, use este identificador para citar o enlazar este ítem:
http://repositorio.ucsg.edu.ec/handle/3317/21680
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Quezada Calle, Edgar Raúl | - |
dc.contributor.author | Jara Fernández, Jorge Joel | - |
dc.date.accessioned | 2023-10-05T17:07:42Z | - |
dc.date.available | 2023-10-05T17:07:42Z | - |
dc.date.issued | 2023-09-15 | - |
dc.identifier.uri | http://repositorio.ucsg.edu.ec/handle/3317/21680 | - |
dc.description | El presente trabajo de integración curricular tiene como objetivo implementar el sistema de descarga temporizada en el compresor del laboratorio de neumática de la Facultad de Educación Técnica para el Desarrollo de la UCSG. Se utilizará el protocolo IP 00/65 y sistemas embebidos para llevar a cabo esta implementación. La descarga temporizada en el compresor de aire es un proceso importante para garantizar su funcionamiento eficiente y prolongar su vida útil. Mediante el uso de sistemas embebidos, se podrá programar y controlar el tiempo de descarga de manera precisa y automática. Además, la utilización del grado de protección IP 00/65, el cual permite una protección frente a la humedad con el fin de proteger la integridad del equipo electrónico. Con la implementación de este sistema, se espera mejorar el rendimiento del compresor y optimizar su operación en el laboratorio de neumática, contribuyendo así al desarrollo y la calidad de la educación técnica en la facultad | en_US |
dc.description.abstract | The objective of this curricular integration work is to implement the timed unloading system in the compressor of the pneumatics laboratory of the Faculty of Technical Education for Development of the UCSG. The IP 00/65 protocol and embedded systems will be used to carry out this implementation. Timed unloading in the air compressor is an important process to ensure its efficient operation and prolong its lifetime. By using embedded systems, the unloading time can be programmed and controlled precisely and automatically. In addition, the use of the IP 00/65 degree of protection, which allows protection against humidity to protect the integrity of the electronic equipment. With the implementation of this system, it is expected to improve the performance of the compressor and optimize its operation in the pneumatics laboratory, thus contributing to the development and quality of technical education in the faculty. | en_US |
dc.format | application/pdf | en_US |
dc.language.iso | spa | en_US |
dc.publisher | Universidad Católica de Santiago de Guayaquil | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/4.0/ | en_US |
dc.subject | VÁLVULA NEUMÁTICA | en_US |
dc.subject | DRENADOR TEMPORIZADO | en_US |
dc.subject | SISTEMA EMBEBIDO | en_US |
dc.subject | COMPRESORES | en_US |
dc.title | Implementación del sistema de descarga temporizada en el compresor del laboratorio de neumática de la FETD-UCSG, utilizando IP 00/65 y sistemas embebidos. | en_US |
dc.type | info:eu-repo/semantics/bachelorThesis | en_US |
Aparece en las colecciones: | Trabajos de Titulación - Carrera de Electrónica y Automatización |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
T-UCSG-PRE-TEC-CIEA-9.pdf | 3,03 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons